Los Angeles EBEWE
EBEWE stands for the Los Angeles Existing Buildings Energy and Water Efficiency Program, a city ordinance requiring building owners to benchmark and disclose their building's energy and water usage annually, with audits and retro-commissioning every five years.
Pegasus is Your Trusted Partner for EBEWE “Compliance”
〰️
Pegasus is Your Trusted Partner for EBEWE “Compliance” 〰️
Ensure seamless EBEWE compliance for your Los Angeles properties with Pegasus. We proactively explore “Beyond Benchmarking” requirements, seeking exemptions to save you time and money. Should an audit be necessary, our team delivers a clear, ROI-focused report.
Join our growing list of satisfied clients. Talk to an experienced professional today:
The EBEWE Ordinance
The Los Angeles Existing Building Energy and Water Efficiency (EBEWE) ordinance requires owners of commercial and multifamily buildings over 20,000 square feet to file an Energy Benchmark report each year by June 1st.
Audit and Retro-Commissioning (A/RCx)
In addition to the annual benchmark report, the ordinance requires the building to have an energy and water audit and retro-commissioning (A/RCx) every 5 years unless it is exempt from the A/RCx. Buildings can qualify for the A/RCx exemption based on Building Performance or Title 24 Compliance.
Energy A/RCx Exemptions
Buildings meeting one of the following energy Performance or Compliance exemptions are not required to undergo an Energy Audit or Retro-Commissioning.
-
Buildings without a central cooling system or with a cooling system with an aggregate input capacity of less than 100 refrigeration tons can retrofit four of the following six energy efficiency measures for Title 24 Compliance:
Energy Star Certification Score of 75: The building has received this certification from the EPA for the year of the building’s compliance due date.
Energy Star Certification Score of 75: The building received this certification from the EPA for two of the three years preceding its compliance due date.
Buildings not eligible for an Energy Star score must perform 25% better than the national median.
The building has achieved a 15% reduction in its Source Energy Use Intensity (EUI) compared to the five years preceding its compliance due date.
-
Install common area and exterior lighting fixtures by Title 24 standards
Pipe insulation following Title 24 standards
Domestic hot water systems installed per Title 24 standards
Cool roof installed under Title 24 standards
Demand response program participation.
Solar thermal hot water heating system installation.
Water A/RCx Exemptions
Buildings meeting one of the following water Performance or Compliance exemptions are not required to undergo an Energy Audit or Retro-Commissioning.
-
The building has reduced water use intensity by at least 20% compared to the five years before its compliance due date.
-
Buildings without a central cooling system or a cooling system that does not operate by water consumption must retrofit two of the following three water efficiency measures for Title 24 Compliance:
Low-flow faucets and shower heads.
Front-loading clothes washing machines.
Water closets and urinals.
There are Some Exemptions to the Ordinance
A building owner is exempt from filing a benchmarking report for a reporting year if any of the following conditions apply:
The building did not have a Certificate of Occupancy or a Temporary Certificate of Occupancy for the entire calendar year required for benchmarking.
The building was unoccupied for the entire year due to renovations.
A demolition permit had been issued, and demolition had begun on or before the reporting deadline.
The building did not receive energy or water services for the entire year to be benchmarked.
Buildings with a triple net lease (NNN) may be exempt
Los Angeles EBEWE FAQs
-
All privately owned buildings 20,000 square feet or more must be benchmarked and registered annually with the City of Los Angeles according to the schedule as defined in the EBEWE Ordinance, in which the last digit of the LABDS Building ID corresponds to the year due, as follows:
0 or 1: December 1, 2021, THEN December 1, 2026
2 or 3: December 1, 2022, THEN December 2027
4 or 5: December 1, 2023, THEN December 2028
6 or 7: December 1, 2024, THEN December 2028
8 or 9: December 1, 2025, THEN December 2029
-
The following buildings are exempted: (be sure to verify with LADBS)
Single-family homes, duplexes, residential hotels, sound stages and other TV and film production facilities.
Hospitals Regulated by OSHPD
Owned by the State or Federal Government
Vacant for entire year, with no Certificate of Occupancy
Vacant for a year due to renovation
Demolition permit issued
No energy or water service for entire year
-
Total water usage
Total electrical usage
Total gas usage
Energy generated by solar panels (which is not part of an electrical bill)
-
The condo homeowner’s association must benchmark the building.
-
LADBS assigns each building a Building ID, a unique identifier needed to register with LADBS and to identify buildings in ENERGY STAR Portfolio Manager. Building IDs are provided in the Ordinance notification letter from LADBS. If you did not receive your notification letter listing your Building ID, you may look it up on the Building Information Online system (BIO).
-
The Property ID differs from the Building ID and can be found in your ENERGY STAR Portfolio Manager account under your property's name and address in the top navigation bar. The Property ID is entered to request data from SoCalGas.
-
Yes, new buildings are subject to the ordinance and need to be benchmarked and registered. The first year of compliance depends on the building’s square footage and is defined in the ordinance.
-
Yes, the LADBS charges an annual registration fee of $64 per building.
-
You can obtain or confirm your Building ID using the LADBS Atlas. Type in the Building ID or address of the property, and the map will highlight the building that corresponds to that given information. If you encounter problems using Atlas that cannot be resolved using the FAQs, please get in touch with LADBS at ladbs.ebewe@lacity.org or (213) 482-0476.
-
Each building needs to be benchmarked separately using the associated Building ID, provided it meets the square footage requirements using its own Building ID.
-
No, you can associate multiple buildings with one (1) LADBS user account.
-
Yes. Registration fees are tied to each building, not each LADBS user account.
-
The Department of Building and Safety has an 82-page instruction guide for sending benchmark data. Basically, the steps are as follows:
Register your Building with LADBS
Create an ENERGY STAR Portfolio Manager account
Add your property to Portfolio Manager by creating a Property Profile
Add property details to Portfolio Manager
Add utility meters to Portfolio Manager
Manually upload your utility data to your Property Profile OR
Request building energy use data from your utilities- this will require:
Proof of Ownership – an electronic copy of the current deed, title report or property tax bill
Building information – address, square footage, and Assessor’s Parcel Number
Tenant Consent form (to release tenant utility data) when:
Building has fewer than 3 commercial active utility accounts (per energy type)
Building has fewer than 5 active utility accounts and at least one of which is residential
A list of utility meters in the building
Exchange the energy use data in Portfolio Manager with the utilities
Run “data quality checker” to ensure that you have sufficient data downloaded from the utilities
Generate a Response Preview in Portfolio Manager
Respond to the Data Request to submit your data to the LADBS
-
To confirm your benchmarking report submission, please contact: ladbs.ebewe@lacity.org. Please be sure to include both the building address and Building ID in your email.
-
Contact Pegasus Energy Solutions. We have been using the ENERGY STAR Portfolio Manager for over 10 years and have generated hundreds of Energy Benchmark Report for clients throughout the state. Our experienced professionals can simplify the process and save you valuable time.
-
Ordinance No. 184674 requires that the following information be made available to the public on Internet:
Summary statistics on overall compliance
Summary statistics on overall energy and water consumption of buildings subject to the EBEWE Ordinance derived from aggregation of annual benchmarking reports; and
Building address and property use type;
The Energy Star® Portfolio Manager Energy Star score for the building, where available;
The weather-normalized site and source energy use intensity (EUI) per unit area per year (kBTU per square foot per year) for the building;
The site and source energy use intensity (EUI) per unit area per year (kBTU per square foot per year) for the building;
The annual carbon dioxide equivalent emissions due to energy use for the building as estimated by ENERGY STAR® Portfolio Manager;
Indoor water use, indoor water intensity, outdoor water use (when available), and total water use; and
The status of compliance with the requirements of the EBEWE ordinance.
-
Your property should be exempt if the tenant is fully responsible for the Base Building System, which is defined as: The systems and subsystems of a building that use or distribute energy and/or water and/or impact the energy and/or water consumption, including:
The building envelope;
the heating ventilating and air conditioning (HVAC) systems;
Air conveying systems;
Electrical and lighting systems;
Domestic hot water systems;
Water distribution systems;
Plumbing fixtures and other water-using equipment;
and landscape irrigation systems and water features.
To request an exemption related to Base Building Systems, send an email to ladbs.arcx@lacity.org and include the following information:
1. Subject Line: Base Bldg System-LADBS Building ID (type the actual number)-Address Number and Street Name. For example, Base Bldg System-123456789101-2134 Somewhere Pl”
2. Body: Describe precisely how your building matches the criteria specified in Sections 91.9704.1, 2 or 3. Also, provide your name, title, and daytime contact phone number.
3. Attach a copy of the lease agreement and other official evidence (such as utility bills) that demonstrate the tenant meets the relevant criteria for Sections 91.9704.1 or 91.9704.2. 4. Attach for Section 91.9704.3, a copy of the most recent Certificate of Occupancy issued by LADBS.
Benchmarking or Beyond —
Start Here and We’ll Guide You.
Not sure what applies to your building? Click below to get in touch — we’ll guide you.
🟦 Benchmarking
Annual compliance for AB 802, EBEWE, BPO, and other ordinances.
🟩 Beyond Benchmarking
Audits, exemptions, retro-commissioning, and ENERGY STAR certification.